Emergency lighting: An overview

Regulations, systems and maintenance explained in a compact and practical manner.

19 March 2026 Fire Safety

Emergency lighting ensures that people can safely leave a building even in the event of a power failure or fire. It illuminates escape and rescue routes, reduces the risk of accidents and helps emergency services to find their way around. It is not only a sensible safety measure – it is also required by law in many buildings.

Why is emergency lighting so important?

When general lighting fails, uncertainty quickly arises. This can have fatal consequences, especially in large buildings such as production facilities, hospitals or meeting places. Functioning emergency lighting:

  • ensures the safe use of escape routes
  • prevents panic and falls
  • enables rapid evacuation
  • supports fire and rescue services

The responsibility lies with the building operator or employer. 

Notbeleuchtung-Ein-Überblick-F-b

Emergency lighting: These regulations apply in Germany

The planning and operation of emergency lighting are subject to clear legal requirements. The most important standards and regulations include:

DIN EN 1838 specifies the requirements for emergency lighting. Among other things, it defines minimum illuminance levels on escape routes, requirements for anti-panic lighting and the marking of emergency exits. The ArbStättV obliges employers to provide adequate safety lighting if hazards could arise in the event of a failure of the general lighting. In addition, the Technical Rules for Workplaces apply.DIN VDE 0108 regulates the professional installation of emergency lighting systems. It describes requirements for power sources, cable routing and monitoring systems. In addition, regular inspections by experts are mandatory.

Types of emergency lighting

Different systems are used depending on the size and use of the building.

Single battery systems are generally used for emergency exit signs and safety lights. Each light has an integrated rechargeable battery.

Features:

  • Self-sufficient power supply
  • Operating time: 1, 3 or 8 hours
  • Easy to retrofit

They are particularly suitable for smaller properties or individual areas of buildings.

In a central battery system (CPS system), several luminaires are supplied via a central power source.

Advantages:

  • Same operating time as single battery systems
  • Central monitoring
  • Simplified maintenance

This solution is economical for larger buildings with many luminaires.

Group battery systems (LPS systems) supply emergency lighting in a decentralised manner within a fire compartment.

Characteristics:

  • Use per fire compartment
  • Minimum service life of 5 years
  • Good balance between centralised and individual solutions

They offer a flexible solution for complex building structures.

Arten-Notbeleuchtung-F-b

Installation and maintenance of emergency lighting

Emergency lighting may only be installed by qualified specialists. Careful planning ensures that:

  • all escape routes are illuminated in accordance with standards
  • emergency signs are positioned correctly
  • the power supply is redundantly secured
Notbeleuchtung-Wartung-CWS Fire Safety

Regular testing is equally important. Emergency lighting systems must be tested at least once a year. In addition, a comprehensive expert inspection in accordance with DIN VDE 0108 is required at specified intervals. The results must be documented in a test log and kept for at least four years.

With a maintenance contract, CWS Fire Safety takes care of the following for you:

  • Regular visual and functional inspections
  • Documentation in accordance with VDE specifications
  • Legally compliant maintenance
Notbeleuchtung-Sicherheitsbeleuchtung-Wartung-CWS Fire Safety

Emergency lighting protects!

Standard-compliant emergency lighting is essential for safety in buildings. It meets legal requirements, minimises liability risks and saves lives in an emergency.

Whether a single battery system, central battery system or group battery system – the right solution depends on the type of building, its use and risk assessment.

Let our experts advise you. Together, we will develop a tailor-made safety concept for your property.

Notbeleuchtung schützt Menschen und Unternehmen-F-f

FAQ

for emergency lighting

Is emergency lighting required by law?

Yes, emergency lighting is required by law in many buildings. The basis for this is the Workplace Ordinance (ArbStättV). It requires safety lighting whenever a failure of the general lighting could pose a hazard to people.

In addition, DIN EN 1838 (requirements for emergency lighting) and DIN VDE 0108 (installation of safety lighting systems) apply. Operators and employers are responsible for ensuring that the systems comply with standards and are operated safely.

How long must emergency lighting function in an emergency?

The prescribed operating time depends on the use and potential hazards of the building. Operating times of 1, 3 or 8 hours are common.

In many workplaces, the minimum operating time is one hour. Longer times may be required in special buildings such as hospitals, meeting places or industrial facilities. The specific design is determined as part of the risk assessment and in accordance with official requirements.

What systems are available for emergency lighting?

Various technical solutions are available for implementing emergency lighting:

  • Individual battery systems with integrated rechargeable batteries for each luminaire
  • Central battery systems (CPS systems) with central power supply and monitoring
  • Group battery systems (LPS systems) for decentralised supply within a fire compartment

The choice depends on the size and structure of the building, the number of luminaires and maintenance requirements.

How often must emergency lighting be checked?

Testing emergency lighting is mandatory. An initial test must be carried out by a competent person before commissioning.

Regular functional tests must be carried out during operation – daily, monthly or annually, depending on the type of system and risk assessment. In addition, a comprehensive expert inspection in accordance with DIN VDE 0108 is required at specified intervals.

All inspections must be documented in an inspection log and kept for at least four years.

Who is responsible for maintenance and operation?

The responsibility lies with the operator of the facility or the employer. They must ensure that the emergency lighting is functional at all times and meets the legal requirements.

Maintenance may only be carried out by qualified specialists – for example, by a competent person in accordance with the Industrial Safety Regulation (BetrSichV), TRBS 1203 and VDE.

Do you have any questions?