Smoke extraction in the stairwell

Learn about the regulations and types of smoke extraction in stairwells.

Entrauchung Treppenhaus Vorschriften-Arten-CWS Fire Safety

Individual expert advice

Non-binding and competent for your industry

Already a customer?
Hidden Fields

Information on the processing of your personal data can be found here

22 May 2024 Fire Safety

Smoke extraction in the stairwell is crucial to ensure a safe escape route in the event of a fire. Smoke extraction openings in the stairwell ensure that toxic fire smoke is extracted and the stairwell remains smoke-free.

Natural smoke extraction in the stairwell

Natürliche Entrauchung im Treppenhaus-CWS Fire Safety

Smoke extraction in the stairwell can be implemented via mechanical and natural smoke extraction openings. Natural smoke extraction uses the chimney effect, i.e. natural air currents and thermal buoyancy forces. Smoke extraction openings are installed in the stairwell in the form of skylights, skylight domes, arcade rooflights or windows on the outer wall. In the event of a fire, these openings are triggered either manually by a manual button or automatically by smoke detectors.

In addition to smoke extraction, a modern smoke extraction system in the stairwell with an electric drive enables regular air exchange, which prevents the formation of mold, for example.

Mechanical smoke extraction in the stairwell

Alternatively, mechanical smoke extraction in the stairwell is possible and often necessary if no openings to the outside can be installed. In the event of a fire, smoke and heat are extracted from the building via ventilation ducts using ventilation and fire gas fans. At the same time, air is exchanged via additional openings or supply air fans.

Maschinelle Entrauchung im Treppenhaus-CWS Fire Safety

Regulations for stairwell smoke extraction

The exact regulations for smoke extraction in stairwells are set out in the state building regulations and vary from state to state. In general, internal stairwells must be equipped with a smoke extraction system, while specific building heights or numbers of storeys apply as a benchmark for external stairwells. For example, the smoke extraction system in the stairwell is generally required for buildings

  • 13 meters or more in height
  • from 5 storeys or
  • with internal stairwells (depending on the building regulations).

The installation and maintenance of a smoke extraction system in the stairwell is subject to various specifications in accordance with DIN, VDE and VdS.

Vorschriften für die Treppenhaus-Entrauchung-CWS Fire Safety
Entrauchung Treppenhaus-Wartung-CWS Fire Safety

Don't forget maintenance!

In addition to professional installation, reliable smoke extraction in stairwells also requires regular maintenance. Annual maintenance by a competent person is therefore mandatory.

As experts in the field of preventive fire protection, we offer comprehensive services for the installation, maintenance and repair of smoke extraction openings in stairwells throughout Germany. Our BHE and VdS-certified specialists guarantee the highest quality and reliability.